(1) The following amendment is adopted as an amendment to the IBC for the Park City Corporation, in IBC, Section 3409.2, exception 3, is modified to read as follows: “3. Designated as historic under a state or local historic preservation program.”
(2) The following amendments are adopted as amendments to the IBC for the Park City Corporation and Park City Fire District:
(a) IBC, Section (F)903.2, is deleted and replaced with the following: “(F)903.2 Where required. Approved automatic sprinkler systems in new buildings and structures shall be provided in the location described in this section.
1. All new construction having more than 6,000 square feet on any one floor, except R-3 occupancy.
2. All new construction having more than two (2) stories, except R-3 occupancy.
3. All new construction in the Historic Commercial Business zone district, regardless of occupancy.
4. All new construction and buildings in the General Commercial zone district where there are side yard setbacks or where one or more side yard setbacks is less than two and one half (2.5) feet per story of height.
5. All existing building within the Historic District Commercial Business zone.”; and
(b) In IBC, Table 1505.1, new footnotes d and e are added as follows: “d. Wood roof covering assemblies are prohibited in R-3 occupancies in areas with a combined rating of more than 11 using Tables 1505.1.1 and 1505.1.2 with a score of 9 for weather factors.
e. Wood roof covering assemblies shall have a Class A rating in occupancies other than R-3 in areas with a combined rating of more than 11 using Tables 1505.1.1 and 1505.1.2 with a score of 9 for weather factors. The owner of the building shall enter into a written and recorded agreement that the Class A rating of the roof covering assembly will not be altered through any type of maintenance process.
|
TABLE 1505.1.1 |
||
|
WILDFIRE HAZARD SEVERITY SCALE |
||
|
RATING |
SLOPE |
VEGETATION |
|
1 |
less than or equal to 10% |
Pinion-juniper |
|
2 |
10.1--20% |
Grass-sagebrush |
|
3 |
greater than 20% |
Mountain brush or softwoods |
|
TABLE 1505.1.2 |
||
|
PROHIBITION/ALLOWANCE OF WOOD ROOFING |
||
|
Rating |
R-3 Occupancy |
All Other Occupancies |
|
Less than or equal to 11 |
Wood roof covering assemblies per Table 1505.1 are allowed
|
Wood roof covering assemblies per Table 1505.1 are allowed
|
|
Greater than or equal to 12 |
Wood roof covering is prohibited |
Wood roof covering assemblies with a Class A rating are allowed”
|
Cite this article: FindLaw.com - Utah Code Title 15A. State Construction and Fire Codes Act § 15A-4-105. Amendments to IBC applicable to Park City Corporation or Park City Fire District - last updated January 01, 2025 | https://codes.findlaw.com/ut/title-15a-state-construction-and-fire-codes-act/ut-code-sect-15a-4-105/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)