The following are adopted as amendments to the IEBC and are applicable statewide:
(1) In IEBC, Section 202, the definition for “Approved” is modified by adding the words “or independent third-party licensed engineer or architect and submitted to the building official” after the word official.
(2) In Section 202, the following definition is added: “BUILDING OFFICIAL. See Code official.”
(3) In Section 202, the definition for “Code official” is deleted and replaced with the following:
“CODE OFFICIAL. The officer or other designated authority having jurisdiction (AHJ) charged with the administration and enforcement of this code.”
(4) In Section 202, the definition for “Existing buildings” is deleted and replaced with the following:
“EXISTING BUILDING. A building that is not a dangerous building and that was either lawfully erected under a prior adopted code, or deemed a legal non-conforming building by the code official.”
(5) In IEBC, Section 302.3, the following is added after the words “code official” in the last sentence: “or independent third-party licensed engineer or architect and submitted to the building official.”
(6) In Section 301.3, the exception is deleted.
(7) Section 503.6 is deleted and replaced with the following:
“503.6 Bracing for unreinforced masonry parapets and other appendages upon reroofing.
Where the intended alteration requires a permit for reroofing and involves removal of roofing materials from more than 25% of the roof area of a building assigned to Seismic Design Category D, E, or F that has parapets constructed of unreinforced masonry or appendages such as cornices, spires, towers, tanks, signs, statuary, etc., the work shall include installation of bracing to resist out-of-plane seismic forces, unless an evaluation demonstrates compliance of such items. Reduced seismic forces are permitted for design purposes.”
(8) Section 706.3.1 is deleted and replaced with the following:
“706.3.1 Bracing for unreinforced masonry bearing wall parapets and other appendages.
Where a permit is issued for reroofing more than 25 percent of the roof area of a building assigned to Seismic Design Category D, E, or F that has parapets constructed of unreinforced masonry or appendages such as cornices, spires, towers, tanks, signs, statuary, etc., the work shall include installation of bracing to resist the reduced International Building Code level seismic forces as specified in Section 303 of this code unless an evaluation demonstrates compliance of such items.”
(9) Section 906.6 is deleted and replaced with the following:
“906.6 Bracing for unreinforced masonry parapets and other appendages upon reroofing.
Where the intended alteration requires a permit for reroofing and involves removal of roofing materials from more than 25% of the roof area of a building assigned to Seismic Design Category D, E, or F that has parapets constructed of unreinforced masonry or appendages such as cornices, spires, towers, tanks, signs, statuary, etc., the work shall include installation of bracing to resist out-of-plane seismic forces, unless an evaluation demonstrates compliance with such items. Reduced seismic forces are permitted for design purposes.”
(10)(a) Section 1006.3 is deleted and replaced with the following:
“1006.3 Seismic loads. Where a change of occupancy results in a building being assigned to a higher risk category, or when a change of occupancy results in a design occupant load increase of 100% or more, the building shall satisfy the requirements of Section 1613 of the International Building Code using full seismic forces.”
(b) In Section 1006.3, exceptions 1 through 4 remain unchanged.
(c) In Section 1006.3, add a new exception 5 as follows:
“5. Where the design occupant load increase is less than 25 occupants and the occupancy category does not change.”
(11) In Section 1011.7.3, exception 2 is deleted.
Cite this article: FindLaw.com - Utah Code Title 15A. State Construction and Fire Codes Act § 15A-3-801. General provisions - last updated January 01, 2025 | https://codes.findlaw.com/ut/title-15a-state-construction-and-fire-codes-act/ut-code-sect-15a-3-801/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)