Telephone Company (Owner)
Name:
Location:
Line Concentrator Equipment Locations
Central Office Terminal:
Remote Terminal:
1. General
1.1 The equipment and materials furnished by the bidder must meet the requirements of paragraphs (a) through (p) of this section.
1.2 Paragraphs (a) through (p) of this section cover the minimum general requirements for line concentrator equipment.
1.3 Paragraph (q) of this section covers requirements for installation, inspection and testing when such service is included as part of the contract.
1.4 Appendix A of this section covers the technical data for application engineering and detailed equipment requirements insofar as they can be established by the owner. Appendix A of this section is to be filled in by the owner.
1.5 This appendix B covers detailed information on the line concentrator equipment, information as to system reliability and traffic capacity as proposed by the bidder. This appendix B shall be filled in by the bidder and must be presented with the bid.
2. Performance Objectives
2.1 Reliability (See paragraph (c) of this section)
2.2 Busy Hour Load Capacity and Traffic Delay (See Paragraph (g) of this section)
3. Equipment Quantities Dependent on System Design
3.1 Transmission Facilities between the Central Office and Remote Terminals
|
Type |
Quantity equipped |
Quantity wired only |
|---|---|---|
4. Power Requirements
4.1 Central Office Terminal
Voltage
Current Drain (Amps) Normal ____, Peak ____
Fuse Qty ____, Size ____, Type ____
Heat Dissipation (BTU/Hr.) ____
4.2 Remote Terminal
AC or DC
Voltage
Current Drain (Amps) Normal ____, Peak ____
Fuse Qty ____, Size ____, Type ____
Heat Dissipation (BTU/Hr.) ____
Power required for heating or cooling equipment in remote bidder-furnished housing
5. Temperature and Humidity Limitations
5.1 Temperature
|
Central office |
Remotea |
|
|---|---|---|
|
Maximum °F (°C)․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
․․․․․․․․․․․․․․․․․․․․․․․ |
․․․․․․․․․․․․․․․․․․․․․․․ |
|
Minimum °F (°C)․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
․․․․․․․․․․․․․․․․․․․․․․․ |
․․․․․․․․․․․․․․․․․․․․․․․ |
a Show conditions outside bidder-furnished housing.
5.2 Relative Humidity
|
Central office |
Remotea |
|
|---|---|---|
|
Maximum․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
․․․․․․․․․․․․․․․․․․․․․․․ |
․․․․․․․․․․․․․․․․․․․․․․․ |
|
Minimum․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
․․․․․․․․․․․․․․․․․․․․․․․ |
․․․․․․․․․․․․․․․․․․․․․․․ |
a Show conditions outside bidder-furnished housing.
6. Explanatory Notes
Cite this article: FindLaw.com - Code of Federal Regulations Title 7. Agriculture § 7.1755.397—Specification for Line Concentrators Detailed Requirements; Bidder Supplied Information - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-7-agriculture/cfr-sect-7-1755-397-app-b/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)