(a) Before a tank car is placed in service, the party assembling the completed car shall furnish to car owner, Bureau of Explosives, and the Secretary, Mechanical Division, Association of American Railroads, a report in proper form certifying that tanks and their equipment comply with all the requirements of this specification and including information as to serial numbers, dates of tests, and ownership marks on tanks mounted on car structure.
(b) Purchaser of tanks shall provide for inspection by a competent inspector as follows:
(1) Inspector shall carefully inspect all material and reject that not complying with § 179.500–5.
(2) Inspector shall stamp his official mark on each forging or seamless tube accepted by him for use in making tanks, and shall verify proper application of heat number to such material by occasional inspections at steel manufacturer's plant.
(3) Inspector shall obtain certified chemical analysis of each heat of material.
(4) Inspector shall make inspection of inside surface of tanks before necking-down, to insure that no seams, cracks, laminations, or other defects exist.
(5) Inspector shall fully verify compliance with specification, verify heat treatment of tank as proper; obtain samples for all tests and check chemical analyses; witness all tests; and report minimum thickness of tank wall, maximum inside diameter, and calculated value of D, for each end of each tank as prescribed in § 179.500–4(c).
(6) Inspector shall stamp his official mark on each accepted tank immediately below serial number, and make certified report (see paragraph (c) of this section) to builder, to company or person for whose use tanks are being made, to builder of car structure on which tanks are to be mounted, to the Bureau of Explosives, and to the Secretary, Mechanical Division, Association of American Railroads.
(c) Inspector's report required herein shall be in the following form:
(Place) __________
(Date) __________
Steel Tanks
It is hereby certified that drawings were submitted for these tanks under AAR Application for Approval ______ and approved by the AAR Committee on Tank Cars under date of ______.
Built for __________ Company
Location at __________
Built by __________ Company
Location at __________
Consigned to ________ Company
Location at __________
Quantity __________
Length (inches) __________
Outside diameter (inches) __________
Marks stamped into tank as required in § 179.500–17 are:
DOT–107A* * * *
Note 1: The marked test pressure substituted for the * * * * on each tank is shown on Record of General Data on Tanks attached hereto.
Serial numbers ___ to ___ inclusive
Inspector's mark __________
Owner's mark __________
Test date __________
Water capacity (see Record of Hydrostatic Tests).
Tare weights (yes or no)(see Record of Hydrostatic Tests).
These tanks were made by process of __________
Steel used was identified as indicated by the attached list showing the serial number of each tank, followed by the heat number.
Steel used was verified as to chemical analysis and record thereof is attached hereto. Heat numbers were stamped into metal. All material was inspected and each tank was inspected both before and after closing in ends; all material accepted was found free from seams, cracks, laminations, and other defects which might prove injurious to strength of tank. Processes of manufacture and heat-treatment of tanks were witnessed and found to be efficient and satisfactory.
Before necking-down ends, each tank was measured at each location prescribed in § 179.500–4(c) and minimum wall thickness in inches at each location was recorded; maximum inside diameter in inches at each location was recorded; value of D in inches at each location was calculated and recorded; maximum fiber stress in wall at location showing larger value for
(D 2 +d2)/(D 2 -d2)
was calculated for 7/10 the marked test pressure and recorded. Calculations were made by the formula:
S=[0.7P(D2 −d2)/(D2 +d2)]
Hydrostatic tests, tensile test of material, and other tests as prescribed in this specification, were made in the presence of the inspector, and all material and tanks accepted were found to be in compliance with the requirements of this specification. Records thereof are attached hereto.
I hereby certify that all of these tanks proved satisfactory in every way and comply with the requirements of Department of Transportation Specification No. 107A* * * *.
(Signed) __________
(Place) __________
(Date) __________
Record of Chemical Analysis of Steel for Tanks
Numbered ___ to ___ inclusive
Size ___ inches outside diameter by ___ inches long
Built by __________ Company
For _______________ Company
|
Tanks rep- |
Chemical analysis |
||||||||
|---|---|---|---|---|---|---|---|---|---|
|
resented |
___________________________________________________________ |
||||||||
|
Heat No. |
(serial Nos.) |
C |
Mn |
P |
S |
Si |
Ni |
Cr |
Mo |
These analyses were made by
(Signed) __________
(Place) __________
(Date) __________
Record of Chemical Analysis of Steel in Tanks
Numbered ___ to ___ inclusive
Size ___ inches outside by ___ inches long
Built by __________ Company
For _______________ Company
|
Heat No.
|
Tanks rep-
resented
by test
(serial Nos.)
|
Elastic
limit
(psi)
|
Tensile
strength
(psi)
|
Elon gation
(percent
in 2
inches)
|
Reduc tion of
area
(percent)
|
|---|---|---|---|---|---|
|
(Signed) __________________________________________________________ |
|
|
(Place) ___________________________________________________________ |
|
|
(Date) ____________________________________________________________ |
|
|
RECORD OF HYDROSTATIC TESTS ON TANKS |
|||
|---|---|---|---|
|
Numbered․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
to․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
inclusive |
|
|
Size․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
inches outside by ․․․․․․․․․․․․․․․․․․․․․․․ |
․․․․․․․ |
inches long |
|
Built by․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
Company |
||
|
For․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
Company |
|
Serial Nos.
of tanks
|
Actual test
pressure (psig)
|
Total expansion
(cubic
cm)
|
Permanent
expansion (cubic
cm)
|
Percent ratio
of permanent
expansion to
total expansion1
|
Tare weight
(pounds)2
|
Capacity in
pounds of
water at 60° F
|
|---|---|---|---|---|---|---|
1 If tests are made by method involving measurement of amount of liquid forced into tank by test pressure, then the basic data on which calculations are made, such as pump factors, temperature of liquid, coefficient of compressibility of liquid, etc., must also be given.
2 Do not include protective housing, but state whether with or without valves.
|
(Signed) ______________________________________ |
Date ____________________________________________ |
|
(Place) _______________________________________ |
|
RECORD OF GENERAL DATA ON TANKS |
|||
|---|---|---|---|
|
Numbered․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
to․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
inclusive |
|
|
Built by․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
Company |
||
|
For․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․․ |
Company |
|
Data obtained as prescribed in § 179.500-4(c) |
||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Marked end of tank |
Other end of tank |
|||||||||
|
Serial No.
of tank
|
(t) Min.
thickness
of wall
in inches
|
(d) Max.
inside
diameter in
inches
|
(D)
Calculated
value ofD
in inches= d+2t
|
(t) Minimum
thickness of
wall in
inches
|
(d) Maximum
inside
diameter
in inches
|
(D)
calculated
value of D
in inches
= d+2t
|
Larger
value of
the factor
D2+d2/
D2-d2
|
(S)
Calculated
fiber stress
in psi at
7/10 marked
test
pressure
|
Marked
test
pressure
in psi
stamped in
tank
|
Minimum
tensile
strength of
material
in psi
recorded
|
|
(Signed) ______________________________ |
Cite this article: FindLaw.com - Code of Federal Regulations Title 49. Transportation § 49.179.500–18 Inspection and reports - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-49-transportation/cfr-sect-49-179-500-18/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)