(a) The wall thickness after forming of the tank shell, dome shell, and of 2:1 ellipsoidal heads must be not less than specified in § 179.201–1, nor that calculated by the following formula:
t = | Pd | ||
2SE |
Where:
d=Inside diameter in inches;
E=0.9 Welded joint efficiency; except E=1.0 for seamless heads;
P=Minimum required bursting pressure in psig;
S=Minimum tensile strength of plate material in p.s.i. as prescribed in § 179.200–7;
t=Minimum thickness of plate in inches after forming.
(b) The wall thickness after forming of 3:1 ellipsoidal heads must be not less than specified in § 179.201–1, nor that calculated by the following formula:
t = | Pd | x 1.83 | |
2SE |
Where:
d=Inside diameter in inches;
E=0.9 Welded joint efficiency; except E=1.0 for seamless heads;
P=Minimum required bursting pressure in psig;
S=Minimum tensile strength of plate material in p.s.i. as prescribed in § 179.200–7;
t=Minimum thickness of plate in inches after forming.
(c) The wall thickness after forming of a flanged and dished head must be not less than specified in § 179.201–1, nor that calculated by the following formula:
t = | 5PL | ||
6SE |
Where:
E=0.9 Welded joint efficiency; except E=1.0 for seamless heads;
L=Main inside radius to which head is dished, measured on concave side in inches;
P=Minimum required bursting pressure in psig;
S=Minimum tensile strength of plate material in p.s.i. as prescribed in § 179.200–7;
t=Minimum thickness of plate in inches after forming.
(d) If plates are clad with material having tensile strength properties at least equal to the base plate, the cladding may be considered a part of the base plate when determining thickness. If cladding material does not have tensile strength at least equal to the base plate, the base plate alone must meet the thickness requirements.
(e) For a tank constructed of longitudinal sections, the minimum width of bottom sheet of the tank must be 60 inches measured on the arc, but in all cases the width must be sufficient to bring the entire width of the longitudinal welded joint, including welds, above the bolster.
(f) For a tank built of one piece cylindrical sections, the thickness specified for bottom sheet must apply to the entire cylindrical section.
(g) See § 179.200–9 for thickness requirements for a compartmented tank.
Cite this article: FindLaw.com - Code of Federal Regulations Title 49. Transportation § 49.179.200–6 Thickness of plates - last updated October 02, 2022 | https://codes.findlaw.com/cfr/title-49-transportation/cfr-sect-49-179-200-6/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature or via Westlaw before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw's Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)