(a) The following classifications are exempt from shop inspection and plan approval requirements of this part:
(1) Vessels containing water at a pressure not greater than 689 kPa (100 pounds per square inch gauge or “psig”), and at a temperature not above 93 °C (200 °F) including those containing air, the compression of which serves only as a cushion. Air-charging lines may be permanently attached if the air pressure does not exceed 103 kPa (15 psig).
(2) Hot water supply storage tanks heated by steam or any other indirect means when none of the following limitations is exceeded:
(i) A heat input of 58 kW (200,000 B.t.u. per hour);
(ii) A water temperature of 93 °C (200 °F);
(iii) A nominal water-containing capacity of 454 liters (120 gallons); or
(iv) A pressure of 689 kPa (100 psig).
The exemption of any tank under this subparagraph requires that it shall be fitted with a safety relief valve of at least 1–inch diameter, set to relieve below the maximum allowable working pressure of the tank.
(3)(i) Vessels having an internal operating pressure not exceeding 103 kPa (15 psig) with no limitation on size. (See UG–28(f) of section VIII of the ASME Boiler and Pressure Vessel Code (incorporated by reference; see 46 CFR 54.01–1.)
(ii) Cargo tanks of pressure vessel configuration are not included in the exemption in paragraph (a)(3)(i) of this section.
(4) Class I, II, and III pressure vessels that meet the requirements of § 54.01–5(c)(3) and (c)(4).
(5) Condensers and heat exchangers, regardless of size, when the design is such that the liquid phase is not greater than 689 kPa (100 psig) and 200 °F (93 °C) and the vapor phase is not greater than 103 kPa (15 psig) provided that the Officer in Charge, Marine Inspection is satisfied that system overpressure conditions are addressed by the owner or operator.
(b) For fluid conditioner fittings see § 56.15–1 of this subchapter.
Cite this article: FindLaw.com - Code of Federal Regulations Title 46. Shipping § 46.54.01–15 Exemptions from shop inspection and plan approval (modifies U–1(c)(2)) - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-46-shipping/cfr-sect-46-54-01-15/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)