(a) Standard fire test. A “standard fire test” is one which develops in the test furnace a series of time temperature relationships as follows:
|
5 minutes– |
1,000°F. |
|
10 minutes– |
1,300° F. |
|
30 minutes– |
1,550° F. |
|
60 minutes– |
1,700° F. |
(b) “A” Class divisions. “A” Class divisions such as bulkheads and decks, means divisions that are composed of steel or an equivalent metal, suitably stiffened, and made intact with the main structure of the vessel, including the shell, structural bulkheads, or decks. They are constructed so that, if subjected to the standard fire test, they are capable of preventing the passage of flame and smoke for one hour. In addition, they are insulated with approved structural insulation, bulkhead panels, or deck coverings so that the average temperature on the unexposed side does not rise more than 139° C (250°F) above the original temperature, nor does the temperature at any one point, including any joint, rise more than 181° C (325° F) above the original temperature, within the time listed below:
|
Class A-60 |
60 minutes |
|
Class A-30 |
30 minutes |
|
Class A-15 |
15 minutes |
|
Class A-0 |
0 minutes with no insulation requirement |
(c) “B” Class bulkheads. Bulkheads of the “B” Class shall be constructed with approved incombustible materials and made intact from deck to deck and to shell or other boundaries. They shall be so constructed that, if subjected to the standard fire test, they would be capable of preventing the passage of flame for one-half hour.
(d) “C” Class divisions. Bulkheads or decks of the “C” Class shall be constructed of approved incombustible materials, but need meet no requirements relative to the passage of flame.
(e) Steel. Where the term “steel or other equivalent metal” is used in this subpart, it is intended to require a material which, by itself or due to insulation provided, has structural and integrity qualities equivalent to steel at the end of the applicable fire exposure.
(f) Approved material. Where in this subpart approved materials are required, they refer to materials approved under the applicable subparts of Subchapter Q (Specifications) of this chapter, as follows:
|
Deck Coverings |
164.006 |
|
Structural Insulations |
164.007 |
|
Bulkhead Panels |
164.008 |
|
Incombustible Materials |
164.009 |
|
Interior Finishes |
164.012 |
(g) Stairtower. A stairtower is a stairway which penetrates more than a single deck within the same enclosure.
Cite this article: FindLaw.com - Code of Federal Regulations Title 46. Shipping § 46.32.57–5 Definitions—TB/ALL - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-46-shipping/cfr-sect-46-32-57-5/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)