(a) Gauge lines connecting the pressure taps to the mechanical recorder must:
(1) Have a nominal diameter of not less than 3/8 inch, including ports and valves;
(2) Be sloped upwards from the pressure taps at a minimum pitch of 1 inch per foot of length with no visible sag;
(3) Be the same internal diameter along their entire length;
(4) Not include tees, except for the static-pressure line;
(5) Not be connected to more than one differential-pressure bellows and static-pressure element, or to any other device; and
(6) Be no longer than 6 feet.
(b) The differential-pressure pen must record at a minimum reading of 10 percent of the differential-pressure-bellows range for the majority of the flowing period. This requirement does not apply to inverted charts.
(c) The flowing temperature of the gas must be continuously recorded and used in the volume calculations under § 3175.94(a)(1).
(d) The following information must be maintained at the FMP in a legible condition, in compliance with § 3170.7(g) of this part, and accessible to the AO at all times:
(1) Differential-pressure-bellows range;
(2) Static-pressure-element range;
(3) Temperature-element range;
(4) Relative density (specific gravity) of the gas;
(5) Static-pressure units of measure (psia or psig);
(6) Meter elevation;
(7) Meter-tube inside diameter;
(8) Primary device type;
(9) Orifice-bore or other primary-device dimensions necessary for device verification, Beta- or area-ratio determination, and gas-volume calculation;
(10) Make, model, and location of approved isolating flow conditioners, if used;
(11) Location of the downstream end of 19–tube-bundle flow straighteners, if used;
(12) Date of last primary-device inspection; and
(13) Date of last meter verification.
(e) The differential pressure, static pressure, and flowing temperature elements must be operated between the lower- and upper-calibrated limits of the respective elements.
Cite this article: FindLaw.com - Code of Federal Regulations Title 43. Public Lands: Interior § 43.3175.91 Installation and operation of mechanical recorders - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-43-public-lands-interior/cfr-sect-43-3175-91/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)