Table 5—Canister Bench Tests and Requirements for Front-Mounted and Back-Mounted Gas Mask Canisters | |||||||
---|---|---|---|---|---|---|---|
[42 CFR part 84, subpart I] | |||||||
Test atmosphere | |||||||
Canister type | Test condition | Gas or vapor | Concentration (parts per million) | Flow rate (liters per minute) | Number of tests | Maximum allowable penetration (parts per million) | Minimum service life (minutes)1 |
Acid gas․․․․․․․․․․․․․․․․․․ | As received | SO2 | 20,000 | 64 | 3 | 5 | 12 |
Equilibrated | Cl2 | 20,000 | 64 | 3 | 5 | 12 | |
․․․․․․․․․․ | SO2 | 20,000 | 32 | 4 | 5 | 12 | |
․․․․․․․․․․ | Cl2 | 20,000 | 32 | 4 | 5 | 12 | |
Organic vapor․․․․․․․․․․․․․ | As received | CCl4 | 20,000 | 64 | 3 | 5 | 12 |
Equilibrated | CCl4 | 20,000 | 32 | 4 | 5 | 12 | |
Ammonia․․․․․․․․․․․․․․․․․․․ | As received | NH3 | 30,000 | 64 | 3 | 50 | 12 |
Equilibrated | NH3 | 30,000 | 32 | 4 | 50 | 12 | |
Carbon monoxide․․․․․․․․․․․ | As received | CO | 20,000 | 4 64 | 2 | (3) | 60 |
Equilibrated | CO | 5,000 | 2 32 | 3 | (3) | 60 | |
․․․․․․․․․․ | CO | 3,000 | 2 32 | 3 | (3) | 60 | |
Combination of 2 or 3 of above types5 | |||||||
Combination of all above types6 |
1 Minimum life will be determined at the indicated penetration.
2 Relative humidity of test atmosphere will be 95±3pct; temperature of test atmosphere will be 25±2.5 °C.
3 Maximum allowable CO penetration will be 385 cm3 during the minimum life. The penetration shall not exceed 500 p/m during this time.
4 Relative humidity of test atmosphere will be 95±3pct; temperature of test atmosphere entering the test fixture will be 0±2.5 °C-0 °C.
5 Test conditions and requirements will be applicable as shown in this table.
6 Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and ammonia will be 6 min instead of 12 min.
Table 6—Canister Bench Tests and Requirements for Chin-Style Gas Mask Canisters | |||||||
---|---|---|---|---|---|---|---|
[42 CFR part 84, subpart I] | |||||||
Test atmosphere | |||||||
Canister type | Test condition | Gas or vapor | Concentration (parts per million) | Flow rate (liters per minute) | Number of tests | Maximum allowable penetration (parts per million) | Minimum service life (minutes)1 |
Acid gas․․․․․․․․․․․․․․․․․․ | As received Equilibrated | SO2 | 50,000 | 64 | 3 | 5 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | ․․․․․․․․․․ | Cl2 | 5,000 | 64 | 3 | 5 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | ․․․․․․․․․․ | SO2 | 5,000 | 32 | 4 | 5 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | ․․․․․․․․․․ | Cl2 | 5,000 | 32 | 4 | 5 | 12 |
Organic vapor․․․․․․․․․․․․․ | As received Equilibrated | CCl4 | 5,000 | 64 | 3 | 5 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | ․․․․․․․․․․ | CCl4 | 5,000 | 32 | 4 | 5 | 12 |
Ammonia․․․․․․․․․․․․․․․․․․․ | As received Equilibrated | NH3 | 5,000 | 64 | 3 | 50 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | As received Equilibrated | NH3 | 5,000 | 32 | 4 | 50 | 12 |
Carbon monoxide․․․․․․․․․․․ | As received | CO | 20,000 | 2 64 | 2 | (3) | 60 |
․․․․․․․․․․ | CO | 5,000 | 4 32 | 3 | (3) | 60 | |
․․․․․․․․․․ | CO | 3,000 | 2 32 | 3 | (3) | 60 | |
Combination of 2 or 3 of above types5 | |||||||
Combination of all above types6 |
1 Minimum life will be determined at the indicated penetration.
2 Relative humidity of test atmosphere will be 95±3pct; temperature of test atmosphere will be 25±2.5 °C.
3 Maximum allowable CO penetration will be 385 cm3 during the minimum life. The penetration shall not exceed 500 p/m during this time.
4 Relative humidity of test atmosphere will be 95±3pct; temperature of test atmosphere entering the test fixture will be 0±2.5 °C-0 °C.
5 Test conditions and requirements will be applicable as shown in this table.
6 Test conditions and requirements will be applicable as shown in this table, except the minimum service lives for acid gas, organic vapor, and ammonia will be 6 min instead of 12 min.
Table 7—Canister Bench Tests and Requirements for Escape Gas Mask Canisters | |||||||
---|---|---|---|---|---|---|---|
[42 CFR part 84, subpart I] | |||||||
Test atmosphere | |||||||
Canister type | Test condition | Gas or vapor | Concentration (parts per million) | Flow rate (liters per minute) | Number of tests | Maximum allowable penetration (parts per million) | Minimum service life (minutes)1 |
Acid gas․․․․․․․․․․․․․․․․․․ | As received | SO2 | 5,000 | 64 | 3 | 5 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | Equilibrated | Cl2 | 5,000 | 64 | 3 | 5 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | ․․․․․․․․․․ | SO2 | 5,000 | 32 | 4 | 5 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | ․․․․․․․․․․ | Cl2 | 5,000 | 32 | 4 | 5 | 12 |
Organic vapor․․․․․․․․․․․․․ | As received | CCl4 | 5,000 | 64 | 3 | 5 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | Equilibrated | CCl4 | 5,000 | 32 | 4 | 5 | 12 |
Ammonia․․․․․․․․․․․․․․․․․․․ | As received | NH3 | 5,000 | 64 | 3 | 50 | 12 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | Equilibrated | NH3 | 5,000 | 32 | 4 | 50 | 12 |
Carbon monoxide․․․․․․․․․․․ | As received | CO | 10,000 | 2 32 | 2 | (3) | 4 60 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | ․․․․․․․․․․ | CO | 5,000 | 5 32 | 3 | (3) | 60 |
․․․․․․․․․․․․․․․․․․․․․․․․․․ | ․․․․․․․․․․ | CO | 3,000 | 2 32 | 3 | (3) | 60 |
1 Minimum life will be determined at the indicated penetration.
2 Relative humidity of test atmosphere will be 95±3pct; temperature of test atmosphere will be 25±2.5 °C.
3 Maximum allowable CO penetration will be 385 cm3 during the minimum life. The penetration shall not exceed 500 p/m during this time.
4 If effluent temperature exceeds 100 °C during this test, the escape gas mask shall be equipped with an effective heat exchanger.
5 Relative humidity of test atmosphere will be 95±3 pct; temperature of test atmosphere entering the test fixture will be 0±2.5 °C-0 °C.
Cite this article: FindLaw.com - Code of Federal Regulations Title 42. Public Health 42 CFR Pt. 84, Subpt. I, Tbls. TABLES TO SUBPART I OF PART 84 - last updated October 02, 2022 | https://codes.findlaw.com/cfr/title-42-public-health/cfr-pt-42-84-subpt-i-tbls/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature or via Westlaw before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw's Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)