(a) In addition to the components of the plan listed in § 60.5735a, a state plan submittal to the EPA must include the information in paragraphs (a)(1) through (8) of this section. This information must be submitted to the EPA as part of your plan submittal but will not be codified as part of the federally enforceable plan upon approval by EPA.
(1) You must include a summary of how you determined each standard of performance for each designated facility according to § 60.5755a(a). You must include in the summary an evaluation of the applicability of each of the following heat rate improvements to each designated facility:
(i) Neural network/intelligent sootblowers;
(ii) Boiler feed pumps;
(iii) Air heater and duct leakage control;
(iv) Variable frequency drives;
(v) Blade path upgrades for steam turbines;
(vi) Redesign or replacement of economizer; and
(vii) Improved operating and maintenance practices.
(2)(i) As part of the summary under paragraph (a)(1) of this section regarding the applicability of each heat rate improvement to each designated facility, you must include an evaluation of the following degree of emission limitation achievable through application of the heat rate improvements:
Table 1 to Paragraph (a)(2)(i)—Most Impactful HRI Measures and Range of Their HRI Potential (%) by EGU Size | ||||||
---|---|---|---|---|---|---|
HRI Measure | < 200 MW | 200-500 MW | >500 MW | |||
Min | Max | Min | Max | Min | Max | |
Neural Network/Intelligent Sootblowers | 0.5 | 1.4 | 0.3 | 1.0 | 0.3 | 0.9 |
Boiler Feed Pumps | 0.2 | 0.5 | 0.2 | 0.5 | 0.2 | 0.5 |
Air Heater & Duct Leakage Control | 0.1 | 0.4 | 0.1 | 0.4 | 0.1 | 0.4 |
Variable Frequency Drives | 0.2 | 0.9 | 0.2 | 1.0 | 0.2 | 1.0 |
Blade Path Upgrade (Steam Turbine) | 0.9 | 2.7 | 1.0 | 2.9 | 1.0 | 2.9 |
Redesign/Replace Economizer | 0.5 | 0.9 | 0.5 | 1.0 | 0.5 | 1.0 |
Improved Operating and Maintenance (O&M) Practices | Can range from 0 to > 2.0% depending on the unit's historical O&M practices. |
(ii) In applying a standard of performance, if you consider remaining useful life and other factors for a designated facility as provided in § 60.24a(e), you must include a summary of the application of the relevant factors in deriving a standard of performance.
(3) You must include a demonstration that each designated facility's standard of performance is quantifiable, permanent, verifiable, and enforceable according to § 60.5755a.
(4) Your plan demonstration must include the information listed in paragraphs (a)(4)(i) through (v) of this section as applicable.
(i) A summary of each designated facility's anticipated future operation characteristics, including:
(A) Annual generation;
(B) CO2 emissions;
(C) Fuel use, fuel prices, fuel carbon content;
(D) Fixed and variable operations and maintenance costs;
(E) Heat rates; and
(F) Electric generation capacity and capacity factors.
(ii) A timeline for implementation.
(iii) All wholesale electricity prices.
(iv) A time period of analysis, which must extend through at least 2035.
(v) A demonstration that each standard of performance included in your plan meets the requirements of § 60.5755a.
(5) Your plan submittal must include certification that a hearing required under § 60.23a(c)on the State plan was held, a list of witnesses and their organizational affiliations, if any, appearing at the hearing, and a brief written summary of each presentation or written submission, pursuant to the requirements of § 60.23a(g).
(6) Your plan submittal must include supporting material for your plan including:
(i) Materials demonstrating the State's legal authority to implement and enforce each component of its plan, including standards of performance, pursuant to the requirements of §§ 60.26a and 60.5740a(a)(6);
(ii) Materials supporting calculations for designated facility's standards of performance according to § 60.5755a; and
(iii) Any other materials necessary to support evaluation of the plan by the EPA.
(b) You must submit your final plan to the EPA according to § 60.5800a.
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment § 40.60.5740a What must I include in my plan submittal? - last updated October 02, 2022 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-sect-40-60-5740a/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature or via Westlaw before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw's Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)