(a) In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).
(b) The owner or operator shall determine compliance with the particulate matter standards in § 60.422 as follows:
(1) The emission rate (E) of particulate matter shall be computed for each run using the following equation:
E=(cs Qsd)/(PK)
where:
E=emission rate of particulate matter, kg/Mg (lb/ton) of ammonium sulfate produced.
cs=concentration of particulate matter, g/dscm (g/dscf).
Qsd=volumetric flow rate of effluent gas, dscm/hr (dscf/hr).
P=production rate of ammonium sulfate, Mg/hr (ton/hr).
K=conversion factor, 1000 g/kg (453.6 g/lb).
(2) Method 5 shall be used to determine the particulate matter concentration (cs) and volumetric flow rate (Qsd) of the effluent gas. The sampling time and sample volume for each run shall be at least 60 minutes and 1.50 dscm (53 dscf).
(3) Direct measurement using product weigh scales, or the result of computations using a material balance, shall be used to determine the rate (P) of the ammonium sulfate production. If production rate is determined by material balance, the following equations shall be used:
(i) For synthetic and coke oven by-product ammonium sulfate plants:
P=ABCK 1/4
where:
A=sulfuric aid flow rate to the reactor/crystallizer averaged over the time-period taken to conduct the run, liter/min.
B=acid density (a function of acid strength and temperature), g/cc.
C=acid strength, decimal fraction.
K 1/4 =conversion factor, 0.0808 (Mg-min-cc)/(g-hr-liter) [0.0891 (ton-min-cc)/(g-hr-liter)].
(ii) For caprolactam by-product ammonium sulfate plants:
P = DEFK’
where:
D=total combined feed stream flow rate to the ammonium crystallizer before the point where any recycle streams enter the stream averaged over the time-period taken to conduct the test run, liter/min.
E=density of the process stream solution, g/liter.
F=percent mass of ammonium sulfate in the process solution, decimal fraction.
K’ = conversion factor, 6.0 x 10−5 (Mg-min) / (g-hr) [6.614 x 10−5 (ton-min) / (g-hr)].
(4) Method 9 and the procedures in § 60.11 shall be used to determine the opacity.
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment § 40.60.424 Test methods and procedures - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-sect-40-60-424/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)