Your test system must be able to update data, record data and control systems related to operator demand, the dynamometer, sampling equipment, and measurement instruments. Set up the measurement and recording equipment to avoid aliasing by ensuring that the sampling frequency is at least double that of the signal you are measuring, consistent with good engineering judgment; this may require increasing the sampling rate or filtering the signal. Use data acquisition and control systems that can record at the specified minimum frequencies, as follows:
|
Table 1 of § 1065.202—Data Recording and Control Minimum Frequencies |
|||
|---|---|---|---|
|
Applicable test protocol section |
Measured values |
Minimum command and control frequency a |
|
|
§ 1065.510 |
Speed and torque during an engine step-map |
1 Hz |
1 mean value per step. |
|
§ 1065.510 |
Speed and torque during an engine sweep-map |
5 Hz |
1 Hz means. |
|
§ 1065.514; § 1065.530 |
Transient duty cycle reference and feedback speeds and torques |
5 Hz |
1 Hz means. |
|
§ 1065.514; § 1065.530 |
Steady-state and ramped-modal duty cycle reference and feedback speeds and torques |
1 Hz |
1 Hz. |
|
§ 1065.520; § 1065.530; § 1065.550 |
Continuous concentrations of raw or dilute analyzers |
1 Hz. |
|
|
§ 1065.520; § 1065.530 |
Batch concentrations of raw or dilute analyzers |
1 mean value per test interval. |
|
|
§ 1065.550 |
|||
|
§ 1065.530; § 1065.545 |
Diluted exhaust flow rate from a CVS with a heat exchanger upstream of the flow measurement |
1 Hz. |
|
|
§ 1065.530; § 1065.545 |
Diluted exhaust flow rate from a CVS without a heat exchanger upstream of the flow measurement |
5 Hz |
1 Hz means. |
|
§ 1065.530; § 1065.545 |
Intake-air or raw-exhaust flow rate |
1 Hz means. |
|
|
§ 1065.530; § 1065.545 |
Dilution air flow if actively controlled (for example, a partial-flow PM sampling system) d. |
5 Hz |
1 Hz means. |
|
§ 1065.530; § 1065.545 |
Sample flow from a CVS that has a heat exchanger |
1 Hz |
1 Hz. |
|
§ 1065.530; § 1065.545 |
Sample flow from a CVS that does not have a heat exchanger |
5 Hz |
1 Hz means. |
a The specifications for minimum command and control frequency do not apply for CFVs that are not using active control.
b 1 Hz means are data reported from the instrument at a higher frequency, but recorded as a series of 1 s mean values at a rate of 1 Hz.
c For CFVs in a CVS, the minimum recording frequency is 1 Hz. The minimum recording frequency does not apply for CFVs used to control sampling from a CVS utilizing CFVs.
d Dilution air flow specifications do not apply for CVS dilution air.
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment § 40.1065.202 Data updating, recording, and control - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-sect-40-1065-202/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)