As stated in § 63.1565(a)(2), you shall meet each operating limit in the following table that applies to you.
|
TABLE 9 TO SUBPART UUU OF PART 63—OPERATING LIMITS FOR ORGANIC HAP EMISSIONS FROM CATALYTIC CRACKING UNITS |
|||
|---|---|---|---|
|
For each new or existing catalytic cracking unit . . . |
For this type of continuous monitoring system . . . |
For this type of control device . . . |
You shall meet this operating limit . . . |
|
1. Subject to the NSPS for carbon monoxide (CO) in 40 CFR 60.103 or 60.102a(b)(4) |
Continuous emission monitoring system |
Not applicable |
Not applicable. |
|
2. Not subject to the NSPS for CO in 40 CFR 60.103 or 60.102a(b)(4) |
a. Continuous emission monitoring system. |
Not applicable |
Not applicable. |
|
b. Continuous parameter monitoring systems. |
i. Thermal incinerator |
Maintain the daily average combustion zone temperature above the limit established during the performance test; and maintain the daily average oxygen concentration in the vent stream (percent, dry basis) above the limit established during the performance test. |
|
|
ii. Boiler or process heater with a design heat input capacity under 44 MW or a boiler or process heater in which all vent streams are not introduced into the flame zone. |
Maintain the daily average combustion zone temperature above the limit established in the performance test. |
||
|
iii. Flare |
On and after January 30, 2019, the flare must meet the requirements of § 63.670. Prior to January 30, 2019, the flare pilot light must be present at all times and the flare must be operating at all times that emissions may be vented to it, or the flare must meet the requirements of § 63.670. |
||
|
3. During periods of startup, shutdown or hot standby |
Any |
Any |
Meet the requirements in § 63.1565(a)(5). |
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment 40 CFR Pt. 63, Subpt. UUU, Tbl. 9 Table 9 to Subpart UUU of Part 63—Operating Limits for Organic HAP Emissions From Catalytic Cracking Units - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-pt-40-63-subpt-uuu-tbl-9/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)