[As stated in § 63.1566(c)(1), you shall meet each requirement in the following table that applies to you.] |
|||
|---|---|---|---|
|
For each applicable process vent for a new or existing catalytic reforming unit . . . |
If you use . . . |
For this operating limit . . . |
You shall demonstrate continuous compliance during initial catalyst depressuring and purging operations by . . . |
|
1. Option 1 |
Flare |
The flare pilot light must be present at all times and the flare must be operating at all times that emissions may be vented to it |
On and after January 30, 2019, meeting the requirements of § 63.670. Prior to January 30, 2019, collecting flare monitoring data according to § 63.1572 and recording for each 1-hour period whether the monitor was continuously operating and the pilot light was continuously present during each 1-hour period, or meeting the requirements of § 63.670. |
|
2. Option 2 |
a. Thermal incinerator boiler or process heater with a design input capacity under 44 MW or boiler or process heater in which not all vent streams are not introduced into the flame zone |
Maintain the daily average combustion zone temperature above the limit established during the performance test |
Collecting, the hourly and daily temperature monitoring data according to § 63.1572; and maintaining the daily average combustion zone temperature above the limit established during the performance test. |
|
b. No control device |
Operate at all times according to your operation, maintenance, and monitoring plan regarding minimum purging conditions that must be met prior to allowing uncontrolled purge releases |
Recording information to document compliance with the procedures in your operation, maintenance, and monitoring plan. |
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment 40 CFR Pt. 63, Subpt. UUU, Tbl. 21 Table 21 to Subpart UUU of Part 63.—Continuous Compliance With Operating Limits for Organic HAP Emissions From Catalytic Reforming Units - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-pt-40-63-subpt-uuu-tbl-21/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)