Learn About The Law
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Current as of January 02, 2025 | Updated by Findlaw Staff
|
Item of equipment |
Control requirement a |
|---|---|
|
1. Drain or drain hub |
(a) Tightly fitting solid cover (TFSC); or |
|
(b) TFSC with a vent to either a process, or to a control device meeting the requirements of § 63.139(c); or |
|
|
(c) Water seal with submerged discharge or barrier to protect discharge from wind. |
|
|
2. Manhole b |
(a) TFSC; or |
|
(b) TFSC with a vent to either a process or to a control device meeting the requirements of § 63.139(c); or |
|
|
(c) If the item is vented to the atmosphere, use a TFSC with a properly operating water seal at the entrance or exit to the item to restrict ventilation in the collection system. The vent pipe shall be at least 90 cm in length and not exceeding 10.2 cm in nominal inside diameter. |
|
|
3. Lift station |
(a) TFSC; or |
|
(b) TFSC with a vent to either a process, or to a control device meeting the requirements of § 63.139(c); or |
|
|
(c) If the lift station is vented to the atmosphere, use a TFSC with a properly operating water seal at the entrance or exit to the item to restrict ventilation in the collection system. The vent pipe shall be at least 90 cm in length and not exceeding 10.2 cm in nominal inside diameter. The lift station shall be level controlled to minimize changes in the liquid level. |
|
|
4. Trench |
(a) TFSC; or |
|
(b) TFSC with a vent to either a process, or to a control device meeting the requirements of § 63.139(c); or |
|
|
(c) If the item is vented to the atmosphere, use a TFSC with a properly operating water seal at the entrance or exit to the item to restrict ventilation in the collection system. The vent pipe shall be at least 90 cm in length and not exceeding 10.2 cm in nominal inside diameter. |
|
|
5. Pipe |
Each pipe shall have no visible gaps in joints, seals, or other emission interfaces. |
|
6. Oil/water separator |
(a) Equip with a fixed roof and route vapors to a process, or equip with a closed-vent system that routes vapors to a control device meeting the requirements of § 63.139(c); or |
|
(b) Equip with a floating roof that meets the equipment specifications of § 60.693 (a)(1)(i), (a)(1)(ii), (a)(2), (a)(3), and (a)(4). |
|
|
7. Tank |
Maintain a fixed roof and consider vents as process vents.c |
a Where a tightly fitting solid cover is required, it shall be maintained with no visible gaps or openings, except during periods of sampling, inspection, or maintenance.
b Manhole includes sumps and other points of access to a conveyance system.
c A fixed roof may have openings necessary for proper venting of the tank, such as pressure/vacuum vent, j-pipe vent.
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment 40 CFR Pt. 63, Subpt. MMM, Tbl. 4 Table 4 to Subpart MMM of Part 63—Control Requirements for Items of Equipment That Meet the Criteria of § 63.1362(k) - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-pt-40-63-subpt-mmm-tbl-4/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)