For the operating parameter applicable to you, as specified in Table 3 . . . |
You must establish the following operating limit . . . |
And you must monitor, record, and demonstrate continuous compliance using these minimum frequencies . . . |
||
|---|---|---|---|---|
|
Data measurement |
Data recording |
Data averaging period for compliance |
||
|
Absorbers (Wet Scrubbers) |
||||
|
Influent liquid flow |
Minimum inlet liquid flow |
Continuous |
Every 15 minutes |
Daily. |
|
Influent liquid flow rate and gas stream flow rate |
Minimum influent liquid-to-gas ratio a |
Continuous |
Every 15 minutes |
Daily. |
|
Pressure drop |
Pressure drop range |
Continuous |
Every 15 minutes |
Daily. |
|
Sorbent Injection |
||||
|
Sorbent injection rate |
Minimum injection rate |
Continuous |
Every 15 minutes |
Daily. |
|
Sorbent injection carrier gas flow rate |
Minimum carrier gas flow rate |
Continuous |
Every 15 minutes |
Daily. |
|
Fabric Filters |
||||
|
Alarm time |
Maximum alarm time is not established on a site-specific basis but is specified in § 63.605(f)(9) |
Continuous |
Each date and time of alarm start and stop |
Maximum alarm time specified in § 63.605(f)(9). |
|
Wet Electrostatic Precipitator |
||||
|
Secondary voltage |
Secondary voltage range |
Continuous |
Every 15 minutes |
Daily. |
a If you select the regression model option to monitor influent liquid-to-gas ratio as described in Table 3 to this subpart, then you must also continuously monitor (i.e., record every 15 minutes, and use a daily averaging period) blower amperage, blower static pressure (i.e., fan suction pressure), and any other parameters used in the regression model that are not constants.
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment 40 CFR Pt. 63, Subpt. AA, Tbl. 4 Table 4 to Subpart AA of Part 63—Operating Parameters, Operating Limits and Data Monitoring, Recordkeeping and Compliance Frequencies - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-pt-40-63-subpt-aa-tbl-4/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)