For the air pollutant |
You must meet this emission limitation 2 |
Using this averaging time 3 |
And determining compliance using this method 3 |
|---|---|---|---|
|
Cadmium |
0.0026 milligrams per dry standard cubic meter |
3-run average (collect a minimum volume of 2 dry standard cubic meters) |
Performance test (Method 29 at 40 CFR part 60, appendix A-8). Use ICPMS for the analytical finish. |
|
Carbon monoxide |
17 parts per million dry volume |
3-run average (1 hour minimum sample time per run) |
Performance test (Method 10 at 40 CFR part 60, appendix A-4). |
|
Dioxins/furans (total mass basis) |
4.6 nanograms per dry standard cubic meter |
3-run average (collect a minimum volume of 2 dry standard cubic meters) |
Performance test (Method 23 at 40 CFR part 60, appendix A-7). |
|
Dioxins/furans (toxic equivalency basis) |
0.13 nanograms per dry standard cubic meter |
3-run average (collect a minimum volume of 2 dry standard cubic meters) |
Performance test (Method 23 at 40 CFR part 60, appendix A-7). |
|
Hydrogen chloride |
29 parts per million dry volume |
3-run average (For Method 26, collect a minimum volume of 60 liters per run. For Method 26A, collect a minimum volume of 1 dry standard cubic meter per run) |
Performance test (Method 26 or 26A at 40 CFR part 60, appendix A-8). |
|
Lead |
0.015 milligrams per dry standard cubic meter |
3-run average (collect a minimum volume of 2 dry standard cubic meters) |
Performance test (Method 29 at 40 CFR part 60, appendix A-8). Use ICPMS for the analytical finish. |
|
Mercury |
0.0048 milligrams per dry standard cubic meter |
3-run average (For Method 29 an ASTM D6784-02 (Reapproved 2008),4 collect a minimum volume of 2 dry standard cubic meters per run. For Method 30B, collect a minimum sample as specified in Method 30B at 40 CFR part 60, appendix A) |
Performance test (Method 29 or 30B at 40 CFR part 60, appendix A-8) or ASTM D6784-02 (Reapproved 2008).4 |
|
Nitrogen oxides |
53 parts per million dry volume |
3-run average (for Method 7E, 1 hour minimum sample time per run) |
Performance test (Method 7 or 7E at 40 CFR part 60, appendix A-4). |
|
Particulate matter filterable |
34 milligrams per dry standard cubic meter |
3-run average (collect a minimum volume of 1 dry standard cubic meter) |
Performance test (Method 5 or 29 at 40 CFR part 60, appendix A-3 or appendix A-8). |
|
Sulfur dioxide |
11 parts per million dry volume |
3-run average (1 hour minimum sample time per run) |
Performance test (Method 6 or 6c at 40 CFR part 60, appendix A-4). |
|
Fugitive ash |
Visible emissions for no more than 5% of the hourly observation period |
Three 1-hour observation periods |
Visible emission test (Method 22 at 40 CFR part 60, appendix A-7). |
1 The date specified in the state plan can be no later than 3 years after the effective date of approval of a revised state plan or February 7, 2018.
2 All emission limitations are measured at 7 percent oxygen, dry basis at standard conditions. For dioxins/furans, you must meet either the total mass basis limit or the toxic equivalency basis limit.
3 In lieu of performance testing, you may use a CEMS or, for mercury, an integrated sorbent trap monitoring system, to demonstrate initial and continuing compliance with an emissions limit, as long as you comply with the CEMS or integrated sorbent trap monitoring system requirements applicable to the specific pollutant in §§ 60.2710 and 60.2730. As prescribed in § 60.2710(u), if you use a CEMS or integrated sorbent trap monitoring system to demonstrate compliance with an emissions limit, your averaging time is a 30-day rolling average of 1-hour arithmetic average emission concentrations.
4 Incorporated by reference, see § 60.17.
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment 40 CFR Pt. 60, Subpt. DDDD, Tbl. 6 Table 6 to Subpart DDDD of Part 60—Model Rule—Emission Limitations That Apply to Incinerators on and After [Date To Be Specified in State Plan] 1] - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-pt-40-60-subpt-dddd-tbl-6/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.