For the air pollutant |
You must meet this emission limitation 1 |
Using this averaging time 2 |
|
|---|---|---|---|
|
Cadmium |
0.0014 milligrams per dry standard cubic meter |
3-run average (collect a minimum volume of 4 dry standard cubic meters per run) |
Performance test (Method 29 at 40 CFR part 60, appendix A-8). Use ICPMS for the analytical finish. |
|
Carbon monoxide |
90 (long kilns)/190 (preheater/precalciner) parts per million dry volume |
3-run average (1 hour minimum sample time per run) |
Performance test (Method 10 at 40 CFR part 60, appendix A-4). |
|
Dioxins/furans (total mass basis) |
0.51 nanograms per dry standard cubic meter |
3-run average (collect a minimum volume of 4 dry standard cubic meters per run) |
Performance test (Method 23 at 40 CFR part 60, appendix A-7). |
|
Dioxins/furans (toxic equivalency basis) |
0.075 nanograms per dry standard cubic meter |
3-run average (collect a minimum volume of 4 dry standard cubic meters) |
Performance test (Method 23 at 40 CFR part 60, appendix A-7). |
|
Hydrogen chloride |
3.0 parts per million dry volume |
3-run average (1 hour minimum sample time per run) or 30-day rolling average if HCl CEMS is being used |
If a wet scrubber or dry scrubber is used, performance test (Method 321 at 40 CFR part 63, appendix A). If a wet scrubber or dry scrubber is not used, HCl CEMS as specified in § 60.2145(j). |
|
Lead |
0.014 milligrams per dry standard cubic meter |
3-run average (collect a minimum volume of 4 dry standard cubic meters) |
Performance test (Method 29 at 40 CFR part 60, appendix A-8). Use ICPMS for the analytical finish. |
|
Mercury |
0.0037 milligrams per dry standard cubic meter. Or 21 pounds/million tons of clinker 3 |
30-day rolling average |
Mercury CEMS or integrated sorbent trap monitoring system (performance specification 12A or 12B, respectively, of appendix B and procedure 5 of appendix F of this part), as specified in § 60.2145(j). |
|
Nitrogen oxides |
200 parts per million dry volume |
30-day rolling average |
Nitrogen oxides CEMS (performance specification 2 of appendix B and procedure 1 of appendix F of this part). |
|
Particulate matter (filterable) |
4.9 milligrams per dry standard cubic meter |
3-run average (collect a minimum volume of 2 dry standard cubic meters) |
Performance test (Method 5 or 29 at 40 CFR part 60, appendix A-3 or appendix-8). |
|
Sulfur dioxide |
28 parts per million dry volume |
30-day rolling average |
Sulfur dioxide CEMS (performance specification 2 of appendix B and procedure 1 of appendix F of this part). |
1 All emission limitations are measured at 7 percent oxygen (except for CEMS and integrated sorbent trap monitoring system data during startup and shutdown), dry basis at standard conditions. For dioxins/furans, you must meet either the Total Mass Basis limit or the toxic equivalency basis limit.
2 In lieu of performance testing, you may use a CEMS or, for mercury, an integrated sorbent trap monitoring system, to demonstrate initial and continuing compliance with an emissions limit, as long as you comply with the CEMS or integrated sorbent trap monitoring system requirements applicable to the specific pollutant in §§ 60.2145 and 60.2165. As prescribed in § 60.2145(u), if you use a CEMS or integrated sorbent trap monitoring system to demonstrate compliance with an emissions limit, your averaging time is a 30-day rolling average of 1-hour arithmetic average emission concentrations.
3 Alkali bypass and in-line coal mill stacks are subject to performance testing only, as specified in § 60.2145(y)(3). They are not subject to the CEMS, integrated sorbent trap monitoring system, or CPMS requirements that otherwise may apply to the main kiln exhaust.
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment 40 CFR Pt. 60, Subpt. CCCC, Tbl. 7 TABLE 7 TO SUBPART CCCC OF PART 60—EMISSION LIMITATIONS FOR WASTE-BURNING KILNS THAT COMMENCED CONSTRUCTION AFTER JUNE 4, 2010, OR RECONSTRUCTION OR MODIFICATION AFTER AUGUST 7, 2013 - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-pt-40-60-subpt-cccc-tbl-7/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)