Specification |
PM10 |
PM2.5 |
PM10–2.5 |
||||
|---|---|---|---|---|---|---|---|
|
Class I |
Class II |
Class III |
Class II |
Class III |
|||
|
Acceptable concentration range (Rj), μg/m3 |
15-300 |
3-200 |
3-200 |
3-200 |
3-200 |
3-200 |
|
|
Minimum number of test sites |
2 |
1 |
2 |
4 |
2 |
4 |
|
|
Minimum number of candidate method samplers or analyzers per site |
3 |
3 |
3 1 |
3 1 |
3 1 |
3 1 |
|
|
Number of reference method samplers per site |
3 |
3 |
3 1 |
3 1 |
3 1 |
3 1 |
|
|
Minimum number of acceptable sample sets per site for PM10 methods: |
|||||||
|
Rj < 60 μg/m3 |
3 |
||||||
|
Rj > 60 μg/m3 |
3 |
||||||
|
Total |
10 |
||||||
|
Minimum number of acceptable sample sets per site for PM2.5 and PM10–2.5 candidate equivalent methods: |
|||||||
|
Rj < 30 μg/m3 for 24-hr or Rj < 20 μg/m3 for 48-hr samples |
3 |
||||||
|
Rj > 30 μg/m3 for 24-hr or Rj > 20 μg/m3 for 48-hr samples |
3 |
||||||
|
Each season |
10 |
23 |
23 |
23 |
23 |
||
|
Total, each site |
10 |
23 |
23 (46 for two-season sites) |
23 |
23 (46 for two-season sites) |
||
|
Precision of replicate reference method measurements, PRj or RPRj, respectively; RP for Class II or III PM2.5 or PM10–2.5, maximum |
5 μg/m3 or 7% |
2 μg/m3 or 5% |
10% 2 |
10% 2 |
10% 2 |
10% 2 |
|
|
Precision of PM2.5 or PM10–2.5 candidate method, CP, each site |
10% 2 |
15% 2 |
15% 2 |
15% 2 |
|||
|
Slope of regression relationship. |
1 ± 0.10 |
1 ± 0.05 |
1 ± 0.10 |
1 ± 0.10 |
1 ± 0.10 |
1 ± 0.12 |
|
|
Intercept of regression relationship, μg/m3 |
0 ± 5 |
0 ± 1 |
Between: 13.55 - (15.05 x slope), but not less than -1.5; and 16.56 - (15.05 x slope), but not more than +1.5 |
Between: 15.05 - (17.32 x slope), but not less than -2.0; and 15.05 - (13.20 x slope), but not more than +2.0 |
Between: 62.05 - (70.5 x slope), but not less than -3.5; and 78.95 - (70.5 x slope), but not more than +3.5 |
Between: 70.50 - (82.93 x slope), but not less than -7.0; and 70.50 - (61.16 x slope), but not more than +7.0 |
|
|
Correlation of reference method and candidate method measurements |
≥ 0.97 |
≥ 0.97 |
≥ 0.93—for CCV ≤ 0.4; ≥ 0.85 + 0.2 x CCV—for 0.4 ≤ CCV ≤ 0.5; ≥ 0.95—for CCV ≥ 0.5 |
1 Some missing daily measurement values may be permitted; see test procedure.
2 Calculated as the root mean square over all measurement sets.
Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment 40 CFR Pt. 53, Subpt. C, Tbl. C-4 Table C–4 to Subpart C of Part 53—Test Specifications for PM 10, PM 2.5 and PM 10–2.5 Candidate Equivalent Methods - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-pt-40-53-subpt-c-tbl-c-4/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)