Learn About The Law
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Current as of January 02, 2025 | Updated by Findlaw Staff
You must equip diesel engine air intakes with a device to shut down the diesel engine in the event of runaway. Diesel engines that are continuously attended must be equipped with remotely operated, manual, or automatic shutdown devices. Diesel engines that are not continuously attended must be equipped with automatic shutdown devices.
Cite this article: FindLaw.com - Code of Federal Regulations Title 30. Mineral Resources § 30.250.610 Diesel engine air intakes - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-30-mineral-resources/cfr-sect-30-250-610/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)