512.1 The systems and types of energy specified in this section are provided only for purposes of calculating the Energy Cost Budget. They are not requirements for either systems or the type of energy to be used in the Proposed Design or for calculation of Design Energy Cost.
512.2 Internal loads for multi-family high-rise residential buildings are prescribed in Tables 512.2.a and b, Multi–Family High Rise Residential Building Schedules. Internal loads for other building types shall be modeled as noted in this subsection.
|
Table 512.2.a—Multi–Family High Rise Residential Buildings Schedules—One–Zone Dwelling Unit |
|||||
|---|---|---|---|---|---|
|
[Internal loads per dwelling unit Btu/h] |
|||||
|
Hour |
Occupants |
Lights |
Equipment |
||
|
Sensible |
Latent |
Sensible |
Sensible |
Latent |
|
|
1 |
300 |
260 |
0 |
750 |
110 |
|
2 |
300 |
260 |
0 |
750 |
110 |
|
3 |
300 |
260 |
0 |
750 |
110 |
|
4 |
300 |
260 |
0 |
750 |
110 |
|
5 |
300 |
260 |
0 |
750 |
110 |
|
6 |
300 |
260 |
0 |
750 |
110 |
|
7 |
300 |
260 |
0 |
750 |
110 |
|
8 |
210 |
260 |
980 |
1250 |
190 |
|
9 |
100 |
80 |
840 |
2600 |
420 |
|
10 |
100 |
80 |
0 |
1170 |
180 |
|
11 |
100 |
80 |
0 |
1270 |
190 |
|
12 |
100 |
80 |
0 |
2210 |
330 |
|
13 |
100 |
80 |
0 |
2210 |
330 |
|
14 |
100 |
80 |
0 |
1270 |
190 |
|
15 |
100 |
80 |
0 |
1270 |
190 |
|
16 |
100 |
80 |
0 |
1270 |
190 |
|
17 |
100 |
80 |
0 |
1270 |
190 |
|
18 |
300 |
260 |
0 |
3040 |
450 |
|
19 |
300 |
260 |
0 |
3360 |
500 |
|
20 |
300 |
260 |
960 |
1490 |
220 |
|
21 |
300 |
260 |
960 |
1490 |
220 |
|
22 |
300 |
260 |
960 |
1490 |
220 |
|
23 |
300 |
260 |
960 |
1060 |
160 |
|
24 |
300 |
260 |
960 |
1060 |
160 |
|
Table 512.2.b—Multi–Family High Rise Residential Building Schedules—Two–Zone Dwelling Unit |
||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
[Internal loads per dwelling unit Btu/h] |
||||||||||
|
Hour |
Bedrooms & bathrooms |
Other rooms |
||||||||
|
Occupants |
Lights |
Equipment |
Occupants |
Lights |
Equipment |
|||||
|
Sensible |
Latent |
Sensible |
Sensible |
Latent |
Sensible |
Latent |
Sensible |
Sensible |
Latent |
|
|
1 |
300 |
260 |
0 |
750 |
110 |
|||||
|
2 |
300 |
260 |
0 |
750 |
110 |
|||||
|
3 |
300 |
260 |
0 |
750 |
110 |
|||||
|
4 |
300 |
260 |
0 |
750 |
110 |
|||||
|
5 |
300 |
260 |
0 |
750 |
110 |
|||||
|
6 |
300 |
260 |
0 |
750 |
110 |
|||||
|
7 |
300 |
260 |
0 |
750 |
110 |
|||||
|
8 |
210 |
260 |
980 |
1250 |
190 |
|||||
|
9 |
100 |
80 |
840 |
2600 |
420 |
|||||
|
10 |
100 |
80 |
0 |
1170 |
180 |
|||||
|
11 |
100 |
80 |
0 |
1270 |
190 |
|||||
|
12 |
100 |
80 |
0 |
2210 |
330 |
|||||
|
13 |
100 |
80 |
0 |
2210 |
330 |
|||||
|
14 |
100 |
80 |
0 |
1270 |
190 |
|||||
|
15 |
100 |
80 |
0 |
1270 |
190 |
|||||
|
16 |
100 |
80 |
0 |
1270 |
190 |
|||||
|
17 |
100 |
80 |
0 |
1270 |
190 |
|||||
|
18 |
300 |
260 |
0 |
3040 |
450 |
|||||
|
19 |
300 |
260 |
0 |
3360 |
500 |
|||||
|
20 |
300 |
260 |
960 |
1490 |
220 |
|||||
|
21 |
300 |
260 |
960 |
1490 |
220 |
|||||
|
22 |
300 |
260 |
960 |
1490 |
220 |
|||||
|
23 |
300 |
260 |
960 |
1060 |
160 |
|||||
|
24 |
300 |
260 |
960 |
1060 |
160 |
|
Table 512.2.b—Multi–Family High Rise Residential Building Schedules—Two–Zone Dwelling Unit |
||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
[Internal loads per dwelling unit Btu/h] |
||||||||||
|
Hour |
Bedrooms & bathrooms |
Other rooms |
||||||||
|
Occupants |
Lights |
Equipment |
Occupants |
Lights |
Equipment |
|||||
|
Sensible |
Latent |
Sensible |
Sensible |
Latent |
Sensible |
Latent |
Sensible |
Sensible |
Latent |
|
|
1 |
300 |
260 |
0 |
100 |
20 |
0 |
0 |
0 |
650 |
90 |
|
2 |
300 |
260 |
0 |
100 |
20 |
0 |
0 |
0 |
650 |
90 |
|
3 |
300 |
260 |
0 |
100 |
20 |
0 |
0 |
0 |
650 |
90 |
|
4 |
300 |
260 |
0 |
100 |
20 |
0 |
0 |
0 |
650 |
90 |
|
5 |
300 |
260 |
0 |
100 |
20 |
0 |
0 |
0 |
650 |
90 |
|
6 |
300 |
260 |
0 |
100 |
20 |
0 |
0 |
0 |
650 |
90 |
|
7 |
200 |
180 |
680 |
200 |
40 |
100 |
80 |
300 |
1050 |
150 |
|
8 |
110 |
120 |
240 |
200 |
40 |
100 |
80 |
600 |
2400 |
380 |
|
9 |
0 |
0 |
0 |
100 |
20 |
100 |
80 |
0 |
1070 |
160 |
|
10 |
0 |
0 |
0 |
100 |
20 |
100 |
80 |
0 |
1170 |
170 |
|
11 |
0 |
0 |
0 |
100 |
20 |
100 |
80 |
0 |
1170 |
170 |
|
12 |
0 |
0 |
0 |
100 |
20 |
100 |
80 |
0 |
2110 |
310 |
|
13 |
0 |
0 |
0 |
100 |
20 |
100 |
80 |
0 |
2110 |
310 |
|
14 |
0 |
0 |
0 |
100 |
20 |
100 |
80 |
0 |
1170 |
170 |
|
15 |
0 |
0 |
0 |
100 |
20 |
100 |
80 |
0 |
1170 |
170 |
|
16 |
0 |
0 |
0 |
100 |
20 |
100 |
80 |
0 |
1170 |
170 |
|
17 |
0 |
0 |
0 |
100 |
20 |
100 |
80 |
0 |
1170 |
170 |
|
18 |
0 |
0 |
0 |
100 |
20 |
300 |
260 |
0 |
2940 |
430 |
|
19 |
0 |
0 |
0 |
100 |
20 |
300 |
260 |
0 |
3260 |
480 |
|
20 |
100 |
80 |
320 |
300 |
60 |
200 |
180 |
640 |
1190 |
160 |
|
21 |
100 |
80 |
320 |
300 |
60 |
200 |
180 |
640 |
1190 |
160 |
|
22 |
150 |
130 |
480 |
700 |
90 |
150 |
130 |
480 |
790 |
130 |
|
23 |
300 |
260 |
640 |
410 |
70 |
0 |
0 |
320 |
650 |
90 |
|
24 |
300 |
260 |
640 |
410 |
70 |
0 |
0 |
320 |
650 |
90 |
Cite this article: FindLaw.com - Code of Federal Regulations Title 10. Energy § 10.434.512 Internal loads - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-10-energy/cfr-sect-10-434-512/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)