Learn About The Law
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Current as of January 02, 2025 | Updated by Findlaw Staff
(a) Except as provided in paragraph (b) of this section, each metal halide lamp fixture manufactured on or after January 1, 2009, and designed to be operated with lamps rated greater than or equal to 150 watts but less than or equal to 500 watts shall contain—
(1) A pulse-start metal halide ballast with a minimum ballast efficiency of 88 percent;
(2) A magnetic probe-start ballast with a minimum ballast efficiency of 94 percent; or
(3) A nonpulse-start electronic ballast with either a minimum ballast efficiency of 92 percent for wattages greater than 250 watts; or a minimum ballast efficiency of 90 percent for wattages less than or equal to 250 watts.
(b) The standards described in paragraph (a) of this section do not apply to—
(1) Metal halide lamp fixtures with regulated lag ballasts;
(2) Metal halide lamp fixtures that use electronic ballasts that operate at 480 volts; or
(3) Metal halide lamp fixtures that;
(i) Are rated only for 150 watt lamps;
(ii) Are rated for use in wet locations; as specified by the National Fire Protection Association in NFPA 70 (incorporated by reference; see § 431.323); and
(iii) Contain a ballast that is rated to operate at ambient air temperatures above 50°C, as specified in UL 1029, (incorporated by reference; see § 431.323).
(c) Except when the requirements of paragraph (a) of this section are more stringent (i.e., require a larger minimum efficiency value) or as provided by paragraph (e) of this section, each metal halide lamp fixture manufactured on or after February 10, 2017, must contain a metal halide ballast with an efficiency not less than the value determined from the appropriate equation in the following table:
|
Designed to be operated with lamps of the following rated lamp wattage |
Tested input voltage‡‡ |
Minimum standard equation†† % |
|---|---|---|
|
≥50 W and ≤100 W |
Tested at 480 V |
(1/(1+1.24xP$(-0.351))) - 0.020†† |
|
≥50 W and ≤100 W |
All others |
1/(1+1.24xP$(-0.351)) |
|
>100 W and <150† W |
Tested at 480 V |
(1/(1+1.24xP$(-0.351))) - 0.020 |
|
>100 W and <150† W |
All others |
1/(1+1.24xP$(-0.351)) |
|
≥150 ‡ W and ≤250 W |
Tested at 480 V |
0.880 |
|
≥150 ‡ W and ≤250 W |
All others |
For ≥150 W and ≤200 W: 0.880 |
|
For >200 W and ≤250 W: 1/(1+0.876xP$(-0.351)) |
||
|
>250 W and ≤500 W |
Tested at 480 V |
For >250 and <265 W: 0.880 |
|
For ≥265 W and ≤500 W: (1/(1+0.876xP$(-0.351)) - 0.010 |
||
|
>250 W and ≤500 W |
All others |
1/(1+0.876xP$(-0.351)) |
|
>500 W and ≤1000 W |
Tested at 480 V |
For >500 W and ≤750 W: 0.900 |
|
For >750 W and ≤1000 W: 0.000104xP+0.822 |
||
|
For >500 W and ≤1000 W: may not utilize a probe-start ballast |
||
|
>500 W and ≤1000 W |
All others |
For >500 W and ≤750 W: 0.910 |
|
For >750 W and ≤1000 W: 0.000104xP+0.832 |
||
|
For >500 W and ≤1000 W: may not utilize a probe-start ballast |
† Includes 150 W fixtures specified in paragraph (b)(3) of this section, that are fixtures rated only for 150 W lamps; rated for use in wet locations, as specified by the NFPA 70 (incorporated by reference, see § 431.323), section 410.4(A); and containing a ballast that is rated to operate at ambient air temperatures above 50 °C, as specified by UL 1029 (incorporated by reference, see § 431.323).
‡ Excludes 150 W fixtures specified in paragraph (b)(3) of this section, that are fixtures rated only for 150 W lamps; rated for use in wet locations, as specified by the NFPA 70, section 410.4(A); and containing a ballast that is rated to operate at ambient air temperatures above 50 °C, as specified by UL 1029.
†† P is defined as the rated wattage of the lamp the fixture is designed to operate.
‡‡ Tested input voltage is specified in 10 CFR 431.324.
(d) Except as provided in paragraph (e) of this section, metal halide lamp fixtures manufactured on or after February 10, 2017, that operate lamps with rated wattage >500 W to ≤1000 W must not contain a probe-start metal halide ballast.
(e) The standards described in paragraphs (c) and (d) of this section do not apply to—
(1) Metal halide lamp fixtures with regulated-lag ballasts;
(2) Metal halide lamp fixtures that use electronic ballasts that operate at 480 volts; and
(3) Metal halide lamp fixtures that use high-frequency electronic ballasts.
Cite this article: FindLaw.com - Code of Federal Regulations Title 10. Energy § 10.431.326 Energy conservation standards and their effective dates - last updated January 02, 2025 | https://codes.findlaw.com/cfr/title-10-energy/cfr-sect-10-431-326/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature before relying on it for your legal needs.
A free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw’s Learn About the Law.
Get help with your legal needs
FindLaw’s Learn About the Law features thousands of informational articles to help you understand your options. And if you’re ready to hire an attorney, find one in your area who can help.
Search our directory by legal issue
Enter information in one or both fields (Required)