Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable:

(a) Subpart J—Tungstic Acid Rinse.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any 1 day

Maximum for monthly average

mg/kg (pounds per million pounds) of tungstic acid (as W) produced

Lead

 11.490

 5.333

Zinc

 41.850

 17.230

Ammonia (as N)

5,469.000

2,404.000

(b) Subpart J—Acid Leach Wet Air Pollution Control.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any 1 day

Maximum for monthly average

mg/kg (pounds per million pounds) of tungstic acid (as W) produced

Lead

1.003

0.466

Zinc

3.653

1.504

Ammonia (as N)

477.400

209.900

(c) Subpart J—Alkali Leach Wash.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any 1 day

Maximum for monthly average

mg/kg (pounds per million pounds) of sodium tungstate (as W) produced

Lead

0.000

0.000

Zinc

0.000

0.000

Ammonia (as N)

0.000

0.000

(d) Subpart J—Alkali Leach Wash Condensate.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any 1 day

Maximum for monthly average

mg/kg (pounds per million pounds) of sodium tungstate (as W) produced

Lead

 5.372

 2.494

Zinc

 19.570

 8.057

Ammonia (as N)

2,557.000

1,124.000

(e) Subpart J—Ion Exchange Raffinate (Commingled With Other Process or Nonprocess Waters).

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any 1 day

Maximum for monthly average

mg/kg (pounds per million pounds) of ammonium tungstate (as W) produced

Lead

 24.780

 11.500

Zinc

 90.240

 37.160

Ammonia (as N)

11,790.000

5,185.000

(f) Subpart J—Ion Exchange Raffinate (Not Commingled With Other Process or Nonprocess Waters).

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any 1 day

Maximum for monthly average

mg/kg (pounds per million pounds) of ammonium tungstate (as W) produced

Lead

 24.780

 11.500

Zinc

 90.240

 37.160

Ammonia (as N)1

11,790.000

5,185.000

1 The effluent limitation for this pollutant does not apply if a) the motor liquor feed to the ion exchange process or the raffinate from the ion exchange process contains sulfates at concentrations exceeding 1000 mg/1; b) this mother liquor or raffinate is treated by ammonia steam stripping; and c) such mother liquor or raffinate is not commingled with any other process or nonprocess waters prior to steam stripping for ammonia removal.

(g) Subpart J—Calcium Tungstate Precipitate Wash.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any one day

Maximum for monthly average

mg/kg (pounds per/million pounds) of calcium tungstate (as W) produced

Lead

 20.670

 9.594

Zinc

 75.280

 31.000

Ammonia (as N)

9,838.000

4,325.000

(h) Subpart J—Crystallization and Drying of Ammonium Paratungstate.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any one day

Maximum for monthly average

mg/kg (pounds per/million pounds) of ammonium paratungstate (as W) produced

Lead

0.000

0.000

Zinc

0.000

0.000

Ammonia (as N)

0.000

0.000

(i) Subpart J—Ammonium Paratungstate Conversion to Oxides Wet Air Pollution Control.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any one day

Maximum for monthly average

mg/kg (pounds per/million pounds) of tungstic oxide (as W) produced

Lead

0.773

0.359

Zinc

2.817

1.160

Ammonia (as N)

368.200

161.900

(j) Subpart J—Ammonium Paratungstate Conversion to Oxides Water of Formation.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any one day

Maximum for monthly average

mg/kg (pounds per/million pounds) of tungstic oxide (as W) produced

Lead

0.018

0.008

Zinc

0.064

0.026

Ammonia (as N)

8.398

3.692

(k) Subpart J—Reduction to Tungsten Wet Air Pollution Control.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any one day

Maximum for monthly average

mg/kg (pounds per/million pounds) of tungsten metal produced

Lead

0.862

0.400

Zinc

3.142

1.294

Ammonia (as N)

410.600

180.500

(l) Subpart J—Reduction to Tungsten Water of Formation.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any one day

Maximum for monthly average

mg/kg (pounds per/million pounds) of tungsten metal produced

Lead

0.137

0.064

Zinc

0.499

0.205

Ammonia (as N)

65.190

28.660

(m) Subpart J—Tungsten Powder Acid Leach and Wash.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any 1 day

Maximum for monthly average

mg/kg (pounds per million pounds) of tungsten metal produced

Lead

0.672

0.312

Zinc

2.448

1.008

Ammonia (as N)

319.900

140.700

(n) Subpart J—Molybdenum Sulfide Precipitation Wet Air Pollution Control.

BAT EFFLUENT LIMITATIONS

Pollutant or pollutant property

Maximum for any 1 day

Maximum for monthly average

mg/kg (pounds per million pounds) of tungsten metal produced

Lead

0.000

0.000

Zinc

0.000

0.000

Ammonia (as N)

0.000

0.000

Cite this article: FindLaw.com - Code of Federal Regulations Title 40. Protection of Environment § 40.421.103 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable - last updated October 02, 2022 | https://codes.findlaw.com/cfr/title-40-protection-of-environment/cfr-sect-40-421-103.html