Alabama Code Title 9. Conservation and Natural Resources § 9-17-121
Current as of December 30, 2022 | Updated by FindLaw Staff
Welcome to FindLaw's Cases & Codes, a free source of state and federal court opinions, state laws, and the United States Code. For more information about the legal concepts addressed by these cases and statutes, visit FindLaw's Learn About the Law.
The following LP-gas room heaters may be installed in a residence that is a one- or two-family dwelling and that is not a manufactured home (mobile home) or a modular home as provided in this section:
(1) One listed wall-mounted LP-gas unvented room heater equipped with an oxygen depletion safety shut-off system may be installed in the bathroom of a residential one- or two-family dwelling provided that the input rating shall not exceed 6000 BTU per hour and combustion and ventilation air is provided in accordance with the National Fuel Gas Code, NFPA 54, as adopted by the board.
(2) One listed wall-mounted LP-gas unvented room heater equipped with an oxygen depletion safety shut-off system may be installed in the bedroom of a residential one- or two-family dwelling provided that the input rating shall not exceed 10,000 BTU per hour and combustion and ventilation air is provided as specified in the National Fuel Gas Code, NFPA 54, as adopted by the board.
Cite this article: FindLaw.com - Alabama Code Title 9. Conservation and Natural Resources § 9-17-121 - last updated December 30, 2022 | https://codes.findlaw.com/al/title-9-conservation-and-natural-resources/al-code-sect-9-17-121/
FindLaw Codes may not reflect the most recent version of the law in your jurisdiction. Please verify the status of the code you are researching with the state legislature or via Westlaw before relying on it for your legal needs.
Was this helpful?